DESCRIPTION

The SPA amplifiers are primarily designed for integration into Voice Alarm systems, but thanks to its flexibility, it can also be used for any Public Address or Commercial application. SPA amplifiers are certified to the EN54-16 standard.

The SPA are 2U high 19” rack mountable, 2-channel power amplifiers. Transformer isolated for 100 V, 70 V and 8 Ohm low-impedance distributed loudspeaker systems.

There SPA amplifiers range comprises three models:

The SPA can be powered by either a 220 VAC mains supply or 24 VDC supply able to support a battery back-up system for use in the event of mains failure and emergency evacuation systems.

SPA amplifiers have short-to-ground, short-circuit, overload and temperature overheat protection including line-impedance surveillance with a maximum of 5% deviation using the DIVA8 or IDA8 systems for loudspeaker-line surveillance. They support both single spur and redundant loop (A/B) cabling.

FEATURES

Models:



SPECIFICATIONS

Mains power supply

  • Voltage: 230 VAC +/- 10%, 50/60 Hz
  • Power consumption** standby - idle* - Pmax
    • SPA-2120: 28 W - 150 W - 322 W
    • SPA-2240: 64 W - 287 W - 655 W
  • ** (Total Mains-power consumption)
  • * Idle: Measured with 10 Volt surveillance tone on the output

Battery power supply

  • Voltage: 21-28 VDC
  • Power consumption*** standby - idle* - Pmax
    • SPA-2120: 0.25 A - 2.9 A - 6.4 A
    • SPA-2240: 0.30 A - 5.47 A - 12.3 A
  • *** (Per ch. @ 28 VDC)
  • * (Alarm cycle + 10 V pilot-tone @ 28 VDC)
  • Line inputs: 2 (one per channel)
  • Connector: 3-pin XLR and 3-pin Phoenix

  • Frequency response: +/- 3 dB @ 40 Hz and 20k Hz
  • S/N: > 90 dB
  • THD: < 1% @ 1k Hz
  • Input range: -6 dBV to 6 dBV / 770 mV
  • Input impedance: 22k Ohms

Loudspeakers outputs

SPA-2120

  • Rated load resistance: 100 Ohms (100 V) - 50 Ohms (70 V)
  • Rated load capacitance: 60 nF (100 V) - 125 nF (70 V)
  • Rated output power (per channel): 120 W (cont at 40° C)
  • Frequency response: 40 Hz to 20k Hz (-3 dB)
  • S/N: >  90 dB (no pilot tone)
  • Crosstalk: < 80 dB at nominal load for 1k Hz
  • Distortion: < 1% (@ 1k Hz) @ -10 dB of rated output power

SPA-2240

  • Rated load resistance: 40 Ohms (100 V) - 20 Ohms (70 V)
  • Rated load capacitance: 125 nF (100 V) - 250 nF (70 V)
  • Rated output power (per channel): 240 W (cont at 40° C)
  • Frequency response: 40 Hz to 20k Hz (-3 dB)
  • S/N: >  90 dB (no pilot tone)
  • Crosstalk: < 80 dB at nominal load for 1k Hz
  • Distortion: < 1% (@ 1k Hz) @ -10 dB of rated output power

Environmental

  • Operating temperature: -5° C to +55° C
  • Storage temperature: -40° C to +70° C
  • Relative humidity: 15% to 90%
  • Air pressure: 600 to 1100 h PA

Mechanical

  • Dimensions (H x W x D) 19'' for table top use with feet: 92 x 440 x 305 mm
  • Dimensions (H x W x D) 19'' for rack use with brackets: 88 x 483 x 305 mm
  • Weight:
    • SPA-2060 : 10.6 Kg
    • SPA-2120: 12.3 Kg
    • SPA-2240: 18.5 Kg
  • Mounting 19'' rack-mount
  • Color:  RAL7016


Mains power supply

Voltage: 230 VAC +/- 10%, 50/60 Hz
Power consumption** standby - idle* - Pmax
SPA-2120: 28 W - 150 W - 322 W
SPA-2240: 64 W - 287 W - 655 W
** (Total Mains-power consumption):
* Idle: Measured with 10 Volt surveillance tone on the output

Battery power supply

Voltage: 21-28 VDC
Power consumption*** standby - idle* - Pmax
SPA-2120: 0.25 A - 2.9 A - 6.4 A
SPA-2240: 0.30 A - 5.47 A - 12.3 A
*** (Per ch. @ 28 VDC):
* (Alarm cycle + 10 V pilot-tone @ 28 VDC):
Line inputs: 2 (one per channel)
Connector: 3-pin XLR and 3-pin Phoenix

SPA-2120

Rated load resistance: 100 Ohms (100 V) - 50 Ohms (70 V)
Rated load capacitance: 60 nF (100 V) - 125 nF (70 V)
Rated output power (per channel): 120 W (cont at 40° C)
Frequency response: 40 Hz to 20k Hz (-3 dB)
S/N: >  90 dB (no pilot tone)
Crosstalk: < 80 dB at nominal load for 1k Hz
Distortion: < 1% (@ 1k Hz) @ -10 dB of rated output power

SPA-2240

Rated load resistance: 40 Ohms (100 V) - 20 Ohms (70 V)
Rated load capacitance: 125 nF (100 V) - 250 nF (70 V)
Rated output power (per channel): 240 W (cont at 40° C)
Frequency response: 40 Hz to 20k Hz (-3 dB)
S/N: >  90 dB (no pilot tone)
Crosstalk: < 80 dB at nominal load for 1k Hz
Distortion: < 1% (@ 1k Hz) @ -10 dB of rated output power

Environmental

Operating temperature: -5° C to +55° C
Storage temperature: -40° C to +70° C
Relative humidity: 15% to 90%
Air pressure: 600 to 1100 h PA

Mechanical

Dimensions (H x W x D) 19'' for table top use with feet: 92 x 440 x 305 mm
Dimensions (H x W x D) 19'' for rack use with brackets: 88 x 483 x 305 mm
Weight:
SPA-2060 : 10.6 Kg
SPA-2120: 12.3 Kg
SPA-2240: 18.5 Kg
Mounting 19'' rack-mount:
Color:  RAL7016

APPLICATIONS

Case studies

DOCUMENT DOWNLOADS

Type
Filename
Catalogue
Type: [PDF]
Filename: PAVA_Catalogue
Download:
Brochure
Type: [PDF]
Filename: IDA8 System_Brochure
Download:
Type: [PDF]
Filename: DIVA System_Brochure
Download:
Datasheet
Type: [PDF]
Filename: SPA2120-SPA2240_Datasheet
Download:

Type
Filename
Catalogue
Type: [PDF]
Filename: PAVA_Catalogue
Download:
Brochure
Type: [PDF]
Filename: IDA8_Brochure
Download:
Datasheet
Type: [PDF]
Filename: SPA2120-SPA2240_Fiche produit
Download:
Type: [PDF]
Filename: SPA2060_Fiche produit
Download:

Type
Filename
Brochure
Type: [PDF]
Filename: IDA8 System_Broschüre
Download:
Datasheet
Type: [PDF]
Filename: SPA2120-2240_Datenblatt
Download:
Type: [PDF]
Filename: SPA2060_Datenblatt
Download:

RELATED PRODUCTS

Prima VA

our certified voice alarm solution designed for safety and reliability

Discovery