Pupitres microfónicos IDA8

CD-8AS / CD-16AS

Wallmount Paging Console

  • Compatible with IDA8 Systems
  • 8 / 16 zones
  • All call option
  • Zone selection buttons
  • 1 monitor speaker
  • Fireman microphone
  • EN54-16 certification
Más información >
Wallmount Paging Console
Wallmount Paging Console
Wallmount Paging Console
Wallmount Paging Console

DESCRIPTION

The CD-8AS / CD-16AS consoles use the same architecture as the PPM paging console, with a junction box built into the enclosure for daisy-chaining multiple units (note that only the first console is monitored). The maximum recommended distance between units is 100 m. 

As with the PPM paging console, the CD-8AS / CD-16AS zone buttons can represent a single zone or group of zones and are easily programmed through the system GUI using "drag and drop" functionality. The Push-To-Talk button can be programmed for PTT or latching operation. System status indicators show the status of all zones and indicators are also provided for Power, Evac and Fault.

The CD-8AS / CD-16AS are powered over RS485 via CAT5 (FTP/STP), however if power is not available over RS485 it can be locally powered using a 24 VDC supply.

The CD-8AS / CD-16AS are certified EN54-16 for use on Public Address and Voice Alarm systems.


FEATURES

SPECIFICATIONS

Electrical

  • Power supply: R485 (RJ45/CAT-5)
  • DC / battery power requirements: 
    • Voltage: 18 - 26 VDC
    • Power consumption: 120 mA (CD8-AS) / 150 mA (CD16-AS)

Audio 

  • Frequency response: -3 dB @ 200 to 8k Hz
  • THD: < 1% @ 1k Hz
  • Output level Max: 6 dBu
  • Noise gate threshold: -84 dBu - 24 dBu
  • Attack time: 8 ms
  • Release time: 100 ms
  • Monitoring speaker: 
    • Impedance: 4 Ohms
    • Output power: 1 W @ 1k Hz
    • Frequency response: -3 dB @ 200 to 12k Hz
  • System connection: 
    • Cable type: CAT-5
    • Length: 100 m

Environmental

  • Operating temperature: -5 ºC ~ +55 ºC
  • Storage temperature: -40 ºC ~ +70 ºC
  • Relative humidity: 15% to 90%
  • Air pressure: 600 to 1100 h Pa
  • IP rating: 30
  • Heat Dissipation: 
    • CD8-AS: 10 BTU/hr
    • CD16-AS: 12 BTU/hr

Mechanical

  • Dimensions (W x H x D)
    • CD8-AS: 318.6 x 187 x 130 mm 
    • CD16-AS: 348.6 x 247 x 130 mm
  • Weight
    • CD8-AS: 3.6 Kg 
    • CD16-AS: 4.7 Kg 

Electrical

Power supply: R485 (RJ45/CAT-5)
DC / battery power requirements: 
Voltage: 18 - 26 VDC
Power consumption: 120 mA (CD8-AS) / 150 mA (CD16-AS)

Audio 

Frequency response: -3 dB @ 200 to 8k Hz
THD: < 1% @ 1k Hz
Output level Max: 6 dBu
Noise gate threshold: -84 dBu - 24 dBu
Attack time: 8 ms
Release time: 100 ms
Monitoring speaker: 
Impedance: 4 Ohms
Output power: 1 W @ 1k Hz
Frequency response: -3 dB @ 200 to 12k Hz
System connection: 
Cable type: CAT-5
Length: 100 m

Environmental

Operating temperature: -5 ºC ~ +55 ºC
Storage temperature: -40 ºC ~ +70 ºC
Relative humidity: 15% to 90%
Air pressure: 600 to 1100 h Pa
IP rating: 30
Heat Dissipation: 
CD8-AS: 10 BTU/hr
CD16-AS: 12 BTU/hr

Mechanical

Dimensions (W x H x D)
CD8-AS: 318.6 x 187 x 130 mm 
CD16-AS: 348.6 x 247 x 130 mm
Weight
CD8-AS: 3.6 Kg 
CD16-AS: 4.7 Kg 

APPLICATIONS

Case studies

There is no applications in this category.

DOCUMENT DOWNLOADS

Type
Filename
Catalogar
Type: [PDF]
Filename: PAVA_Catalogue
Download:
Folleto
Type: [PDF]
Filename: IDA8 System_Brochure
Download:
Ficha técnica
Type: [PDF]
Filename: CD-8G2_Datasheet
Download:
Type: [PDF]
Filename: CD-16G2_Datasheet
Download:

Type
Filename
Catalogar
Type: [PDF]
Filename: PAVA_Catalogue
Download:
Folleto
Type: [PDF]
Filename: IDA8_Brochure
Download:

Type
Filename
Folleto
Type: [PDF]
Filename: IDA8 System_Broschüre
Download:
Ficha técnica
Type: [PDF]
Filename: CD-16G2_Datenblatt
Download:
Type: [PDF]
Filename: CD-8G2_Datenblatt